Conductivity meter cm-230 |
|
 |
|
CM-230 Conductivity monitor and the general solution to the water conductivity for a long continuous measurement and monitoring, the use of plug-hole installation, with automatic drift compensation circuit to ensure measurement accuracy of the product, it is widely used in ion exchange, reverse osmosis water equipment raw water and product water conductivity value measurement, monitoring. Keyboard Set-electrode constant, can migrate 4 ~ 20mA current signal output, through the key switch view medium temperature, μS / cm and ppm (TDS) conversion, automatic range switching, optional three kinds of cell constant (0.1cm-1, 1.0 cm-1, 10.0 cm-1), to support a wider range. Ultra-stable measurement acquisition, wide temperature, low drift design, measurement status can be Conductivity / Temperature / TDS switching, high-brightness backlight LCD display. For electrodialysis, reverse osmosis, ion exchange water system, cooling water control systems and general industrial water line monitoring.
|
|
Detailed description |
CM-230 Conductivity Meter Main Technical Performance: Measuring range: 0 ~ 2000μS/cm Divided into 0 ~ 20.00μS/cm, 0 ~ 200.0μS/cm, 0 ~ 2000μS/cm third gear range manually switch; Conductivity: 0 ~ 19.99 0 ~ 199.9μS/cm (0.1cm-1 electrode) 0 ~ 19.99 0 ~ 199.9,0 ~ 1999μS/cm (1.0 cm-1 electrode) 0 ~ 199.9μS/cm 0 ~ 1999μS/cm 0 ~ 19.99mS/cm (10cm-1 electrode) Explicitly: Conductivity 31/2 LCD digital display, digital display temperature 3; Temperature compensation: automatic temperature compensation, base 25 ℃, compensation range 0 ~ 60 ℃; Accuracy: ± 2% (F · S); Electrode configuration: 0.1cm-1316L stainless steel electrodes, 1/2 "(4 points) pipeline threaded connection; 1.00cm-1 Plastic Platinum Electrode, 1/2 "(4 points) pipeline threaded connection; 1.00cm-1 stainless steel electrodes, 1/2 "(4 points) pipeline threaded connection; 10.0 cm-1 Teflon platinum electrode, 3/4 "(6 points) pipeline threaded connection; Cable length: Standard configuration for 5m; Signal output: 4 ~ 20mA current signal (optional conductivity limit alarm output); Instrument Size: Dimensions: 48 × 96 × 100mm (height × width × depth). Hole size: 45 × 91mm (height × width). Instrument Depth: 100 (mm) Instrument Power Supply: AC220V ± 10%, 50Hz; Power consumption: 2W Instrument conditions: Ambient temperature: 0 ~ 50 ℃ Relative humidity: ≤ 85% Medium temperature: 0 ~ 50 ℃ Medium pressure: 0 ~ 0.5MPa. Installation: panel mounting. Warming element: NTC; Accuracy: 1.5% (FS); Stability: ± 1.5 × 10-3 (FS) / 24h; |
|